Designed for beauty care
Designed to complement your salon. Hygiene you can trust. A design you'll want to show off.

Technical Specifications:
The gold standard. Precision engineering.
Dimensions: 56 × 25 × 15.8 cm
Weight: 15 kgPower: 2.25 kW
Power supply voltage: 20–240 V / 50–60 Hz
Working pressure: 2.1 bar
Maximum pressure: 2 .3 bar
Maximum temperature: 137°C
Capacity: 8 sterilization packs
Noise level: 42 dB
Chamber capacity: 2 .7 L
Processes: Vacuum , B&D, Helix
An exceptionally fast 7-minute sterilization cycle
A quick 15-minute cycle with drying
User-friendly touchscreen panel
Medically safe, approved for beauty professionals
Forget about refilling the water
A closed-loop system that allows for up to 1,000 sterilization cycles using just 1 liter of water.
• 1,000 cycles per liter of water
• Up to 6 months without refilling

You might like
Recently viewed items
test
ENBIO S 2.7L Class B Medical Gold Autoclave, Beauty Edition
The Enbio S Beauty Edition is a revolutionary steam sterilizer designed specifically for the beauty industry. It incorporates the most advanced medical technologies, combining them with a minimalist, award-winning design and gold-colored accents for a unique look.
This autoclave guarantees the highest level of safety thanks to the latest Class B technology, which is the only method that ensures complete sterilization effectiveness and safety. The unit is also equipped with a Class S cycle that takes only 7 minutes.
The Enbio S Beauty Edition is a true revolution in the market. It is quiet, compact, and visually appealing, blending seamlessly into the interior of any beauty salon. Short sterilization cycles allow the device to be used even between client visits, while reducing the time the tools are exposed to high temperatures, which significantly extends their service life. In addition, Enbio has low operating costs and is intuitive and easy to use.
The patented technology used allows the sterilization chamber to heat up more quickly and evenly, which shortens sterilization cycles and ensures the robustness and durability of the design.
Enbio complies with all the guidelines of Medical Device Directive 93/42/EEC and the ISO EN 13060 standard as a Class B small steam sterilizer, which confirms its high quality and compliance with medical requirements.
Technical specifications:
- Average electricity consumption per cycle: 0.4–1.75 kWh
- Max. current consumption: 10A
- Installed capacity: 2.25 kW
- Power supply: 220–240 V/50–60 Hz
- Maximum water consumption per cycle: 115 ml
- Permissible water parameters: Demineralized water (hardness <0.02 mmol/l), conductivity (at 20 °C) <15 μS/cm, pH: 5 to 7.5, chemical additives: none
- Operating pressure: 2.1 bar
- Max. pressure: 2.3 bar
- Max. process temperature: 137°C
- Ingress Protection: IP20
- Data Archiving: USB Flash Drive
- Maximum load capacity: 8 bags
- Max. load weight: 500 grams
- Noise level: 38 dB(A)
- Processing chamber capacity: 2.7 L
- Test cycles: Vacuum, B&D, Helix
- Side LED lights: yes
Internal dimensions: 292 x 192 x 45 mm
External dimensions: 561 x 252 x 162 mm
Net weight: 15 kg
Gross weight (including packaging): 17 .3 kg
Warranty: 2 years
Enbio Usage and Maintenance Recommendations
To ensure the safe, effective, and long-lasting operation of the Enbio autoclave, it is important to follow the manufacturer's instructions for use and maintenance:
-
Regular Technical Maintenance
It is recommended that the device undergo technical maintenance every 1,500 sterilization cycles or at least once a year —whichever comes first. Regular maintenance helps maintain the device’s performance and prevent potential technical malfunctions in a timely manner. -
Instruments must be sterilized in sterilization pouches
Instruments to be sterilized must be placed in appropriate sterilization pouches. Sterilizing instruments without pouches may cause damage to the instruments and does not comply with Enbio’s recommended procedure for using the device. -
Ensure adequate ventilation around the device
The Enbio autoclave must not be placed in a closed cabinet, box, niche, or any other location with restricted air circulation. The device must be placed in a freestanding, well-ventilated area, ensuring sufficient airflow around it. Insufficient ventilation may cause the device to overheat, malfunction, or suffer technical damage.
Important: Proper use of the device, regular maintenance, and adherence to the manufacturer's recommendations help ensure the longevity and reliable operation of the Enbio autoclave.